From: | Alan Miles [lord_rootes(at)yahoo.com] |
Sent: | Saturday, October 14, 2006 10:40 AM |
To: | HillmanCars@yahoogroups.com |
Subject: | [HillmanCars] Changing Polarity |
Hi all,
My new Hillman is positive ground. As I will probably want to put a cd player in it eventually I will have to
convert it to negative ground. Can someone tell me what is involved in doing this? I did read one
article on the internet that said along with changing the battery leads around (obviously) and switching the two leads
on the coil one must re-polarize the generator. This, the article said, is done by momentarily (1/2 a second or less)
running a wire from a hot terminal on the ignition or fuse block to the field terminal on the back of the generator.
This article was the only one I found and referred to MGA's so any help or info on differences in doing this to a Minx is appreciated.
Thanks,
Alan M.
From: | Tigerootes(at)aol.com |
Sent: | Saturday, October 14, 2006 12:50 PM |
To: | HillmanCars@yahoogroups.com |
Subject: | Re: [HillmanCars] Changing Polarity |
Alan,
That's about all it takes, but you also have to reverse the wires on your ammeter, if you have one.
Jim
Further relevant information can be found on the Generator Connections page, and to a lesser extent on the Polarising a Generator page.